Cornerstone Power Products
Cornerstone Power Products is a Division of
  • JHB
  • CPT
  • KZN
32 Laub Street
New Centre
Johannesburg
South Africa
Tel: 011 493-9307
29 Mail Street
Western Province Park
Epping
Cape Town
Tel: 021 535-3150
12 Lennox Road
Greyville
Durban
Kwazulu Natal
Tel: 031 309-7686
Order Online
Mantech Electronics Order Online
Tel: +27 (0)11 493-9307
Fax: +27 (0)11 493-9319
Email: cv@mantech.co.za
HOME AC-DC Switch Mode Power Products DC-DC Switch Mode Power Supplies DC-AC Inverters True Sine Wave UPS Systems UPS and Backup Batteries Sheet Metal Battery Cabinets Solar Panels and Wind Turbines

 

Download Titan Online Datasheet

Download PDFDownload Home-Ups Datasheet

 
 
 
 
 

back

 

 

 

 

 

HOME-UPS SERIES

Home-Ups Inverter True Sine Wave, Offline
800 Watt / 1.2Kva - 8000 Watt / 8Kva

The True Sine Wave Home UPS System is a powerful all-in-one solution which delivers unsurpassed clean true sine wave output power and combines this with a selectable multistage battery charging current ability. The Ups System is conducive to a variety of of different loads generally not found in other products.

For Office's, Homes, Server Rooms, Commercial
and Industrial Backup Systems.

 
  • Models
  • Application Example
  • Generl Information
  • 1.2Kva
    800Watt
  • 2.4Kva
    1600Watt
  • 3.6Kva
    2400Watt
  • 5Kva
    4000Watt
  • 6Kva
    6000Watt
  • 8Kva
    8000Watt
1.2Kva - 800 Watts Home-Ups Specification  
NOMINAL INPUT VOLTAGE: 220 VAC  
ACCEPTABLE INPUT VOLTAGE RANGE: 120~270 VAC  
INPUT FREQUENCY: 50 HZ  
LINE LOW TRANSFER: 120 VAC ± 2%  
LINE LOW RETURN: 130 VAC ± 2%  
LINE HIGH TRANSFER: 270 VAC ± 2%  
LINE HIGH RETURN: 260 VAC ± 2%  
     
OUTPUT VOLTAGE: 220 VAC (230VAC AND 240 VAC PROGRAMMABLE VIA LCD PANEL)
OUTPUT VOLTAGE REGULATION: <3% RMS FOR INPUT DC RANGE    
OUTPUT FREQUENCY: 50 HZ ± 1%    
POWER FACTOR: 0.67    
OUTPUT WAVE FORM PURE SINE WAVE    
       
TRANSFER TIME: < 8ms    
BATTERY VOLTAGE: 12 VDC    
BATTERY CHARGER CURRENT 10 AMPS  
SOLAR REGULATOR CURRENT 30 AMPS    
       
DISPAY LCD UPS STATUS - INPUT VOLTAGE - OUTPUT VOLTAGE - MODEL  
  INPUT FREQUENCY - OUTPUT FREQUENCY - TEMPERATURE
  LOAD PRCENTAGE - BATTERY CAPACITY PERCENTAGE  
     
AC FAIL BEEPING EVERY 4 SECONDS  
LOW BATTERY BEEPING EVERY SECOND  
UPS FAULT BEEPING CONTINUOSLY  
OVERLOAD BEEPING TWICE PER SECOND  
OPERATIONAL TEMPERATURE 0-40 DEGREE CELCIUS  
RELATIVE HUMIDITY 0-95% NON-CONDENSING  
AUDIBLE NOISE LESS THAN 55dBA @ 1M  
NET WEIGHT 12 KG  
DIMENSION (WXHXD) mm 298 X 390 X 149
2.4Kva - 1600 Watts Home-Ups Specification
NOMINAL INPUT VOLTAGE: 220 VAC
ACCEPTABLE INPUT VOLTAGE RANGE: 120~270 VAC
INPUT FREQUENCY: 50 HZ
LINE LOW TRANSFER: 120 VAC ± 2%
LINE LOW RETURN: 130 VAC ± 2%
LINE HIGH TRANSFER: 270 VAC ± 2%
LINE HIGH RETURN: 260 VAC ± 2%  
     
OUTPUT VOLTAGE: 220 VAC (230VAC AND 240 VAC PROGRAMMABLE VIA LCD PANEL)
OUTPUT VOLTAGE REGULATION: <3% RMS FOR INPUT DC RANGE    
OUTPUT FREQUENCY: 50 HZ ± 1%    
POWER FACTOR: 0.67    
OUTPUT WAVE FORM PURE SINE WAVE    
       
TRANSFER TIME: < 8ms    
BATTERY VOLTAGE: 24 VDC    
BATTERY CHARGER CURRENT 25 AMPS  
SOLAR REGULATOR CURRENT 30 AMPS    
       
DISPAY LCD UPS STATUS - INPUT VOLTAGE - OUTPUT VOLTAGE - MODEL  
  INPUT FREQUENCY - OUTPUT FREQUENCY - TEMPERATURE
  LOAD PRCENTAGE - BATTERY CAPACITY PERCENTAGE  
     
AC FAIL BEEPING EVERY 4 SECONDS  
LOW BATTERY BEEPING EVERY SECOND  
UPS FAULT BEEPING CONTINUOSLY  
OVERLOAD BEEPING TWICE PER SECOND  
OPERATIONAL TEMPERATURE 0-40 DEGREE CELCIUS  
RELATIVE HUMIDITY 0-95% NON-CONDENSING  
AUDIBLE NOISE LESS THAN 55dBA @ 1M  
NET WEIGHT 27 KG  
DIMENSION (WXHXD) mm 298 X 450 X 190
3.6Kva - 2400 Watts Home-Ups Specification
NOMINAL INPUT VOLTAGE: 220 VAC
ACCEPTABLE INPUT VOLTAGE RANGE: 120~270 VAC
INPUT FREQUENCY: 50 HZ
LINE LOW TRANSFER: 120 VAC ± 2%
LINE LOW RETURN: 130 VAC ± 2%
LINE HIGH TRANSFER: 270 VAC ± 2%
LINE HIGH RETURN: 260 VAC ± 2%  
     
OUTPUT VOLTAGE: 220 VAC (230VAC AND 240 VAC PROGRAMMABLE VIA LCD PANEL)
OUTPUT VOLTAGE REGULATION: <3% RMS FOR INPUT DC RANGE    
OUTPUT FREQUENCY: 50 HZ ± 1%    
POWER FACTOR: 0.67    
OUTPUT WAVE FORM PURE SINE WAVE    
       
TRANSFER TIME: < 8ms    
BATTERY VOLTAGE: 24 VDC    
BATTERY CHARGER CURRENT 25 AMPS  
SOLAR REGULATOR CURRENT 30 AMPS    
       
DISPAY LCD UPS STATUS - INPUT VOLTAGE - OUTPUT VOLTAGE - MODEL  
  INPUT FREQUENCY - OUTPUT FREQUENCY - TEMPERATURE
  LOAD PRCENTAGE - BATTERY CAPACITY PERCENTAGE  
     
AC FAIL BEEPING EVERY 4 SECONDS  
LOW BATTERY BEEPING EVERY SECOND  
UPS FAULT BEEPING CONTINUOSLY  
OVERLOAD BEEPING TWICE PER SECOND  
OPERATIONAL TEMPERATURE 0-40 DEGREE CELCIUS  
RELATIVE HUMIDITY 0-95% NON-CONDENSING  
AUDIBLE NOISE LESS THAN 55dBA @ 1M  
NET WEIGHT 27 KG  
DIMENSION (WXHXD) mm 298 X 450 X 190
5Kva - 4000 Watts Home-Ups Specification
NOMINAL INPUT VOLTAGE: 220 VAC
ACCEPTABLE INPUT VOLTAGE RANGE: 120~270 VAC
INPUT FREQUENCY: 50 HZ
LINE LOW TRANSFER: 120 VAC ± 2%
LINE LOW RETURN: 130 VAC ± 2%
LINE HIGH TRANSFER: 270 VAC ± 2%
LINE HIGH RETURN: 260 VAC ± 2%  
     
OUTPUT VOLTAGE: 220 VAC (230VAC AND 240 VAC PROGRAMMABLE VIA LCD PANEL)
OUTPUT VOLTAGE REGULATION: <3% RMS FOR INPUT DC RANGE    
OUTPUT FREQUENCY: 50 HZ ± 1%    
POWER FACTOR: 0.8    
OUTPUT WAVE FORM PURE SINE WAVE    
       
TRANSFER TIME: < 8ms    
BATTERY VOLTAGE: 24 VDC    
BATTERY CHARGER CURRENT 25 AMPS  
SOLAR REGULATOR CURRENT 30 AMPS    
       
DISPAY LCD UPS STATUS - INPUT VOLTAGE - OUTPUT VOLTAGE - MODEL  
  INPUT FREQUENCY - OUTPUT FREQUENCY - TEMPERATURE
  LOAD PRCENTAGE - BATTERY CAPACITY PERCENTAGE  
     
AC FAIL BEEPING EVERY 4 SECONDS  
LOW BATTERY BEEPING EVERY SECOND  
UPS FAULT BEEPING CONTINUOSLY  
OVERLOAD BEEPING TWICE PER SECOND  
OPERATIONAL TEMPERATURE 0-40 DEGREE CELCIUS  
RELATIVE HUMIDITY 0-95% NON-CONDENSING  
AUDIBLE NOISE LESS THAN 55dBA @ 1M  
NET WEIGHT 70 KG  
DIMENSION (WXHXD) mm 390 X 550 X 235
6Kva - 600 Watts Home-Ups Specification
NOMINAL INPUT VOLTAGE: 220 VAC
ACCEPTABLE INPUT VOLTAGE RANGE: 120~270 VAC
INPUT FREQUENCY: 50 HZ
LINE LOW TRANSFER: 120 VAC ± 2%
LINE LOW RETURN: 130 VAC ± 2%
LINE HIGH TRANSFER: 270 VAC ± 2%
LINE HIGH RETURN: 260 VAC ± 2%  
     
OUTPUT VOLTAGE: 220 VAC (230VAC AND 240 VAC PROGRAMMABLE VIA LCD PANEL)
OUTPUT VOLTAGE REGULATION: <3% RMS FOR INPUT DC RANGE    
OUTPUT FREQUENCY: 50 HZ ± 1%    
POWER FACTOR: 1.0    
OUTPUT WAVE FORM PURE SINE WAVE    
       
TRANSFER TIME: < 8ms    
BATTERY VOLTAGE: 48 VDC    
BATTERY CHARGER CURRENT 25 AMPS  
SOLAR REGULATOR CURRENT 30 AMPS    
       
DISPAY LCD UPS STATUS - INPUT VOLTAGE - OUTPUT VOLTAGE - MODEL  
  INPUT FREQUENCY - OUTPUT FREQUENCY - TEMPERATURE
  LOAD PRCENTAGE - BATTERY CAPACITY PERCENTAGE  
     
AC FAIL BEEPING EVERY 4 SECONDS  
LOW BATTERY BEEPING EVERY SECOND  
UPS FAULT BEEPING CONTINUOSLY  
OVERLOAD BEEPING TWICE PER SECOND  
OPERATIONAL TEMPERATURE 0-40 DEGREE CELCIUS  
RELATIVE HUMIDITY 0-95% NON-CONDENSING  
AUDIBLE NOISE LESS THAN 55dBA @ 1M  
NET WEIGHT 70 KG  
DIMENSION (WXHXD) mm 390 X 550 X 235
8Kva - 8000 Watts Home-Ups Specification
NOMINAL INPUT VOLTAGE: 220 VAC
ACCEPTABLE INPUT VOLTAGE RANGE: 120~270 VAC
INPUT FREQUENCY: 50 HZ
LINE LOW TRANSFER: 120 VAC ± 2%
LINE LOW RETURN: 130 VAC ± 2%
LINE HIGH TRANSFER: 270 VAC ± 2%
LINE HIGH RETURN: 260 VAC ± 2%  
     
OUTPUT VOLTAGE: 220 VAC (230VAC AND 240 VAC PROGRAMMABLE VIA LCD PANEL)
OUTPUT VOLTAGE REGULATION: <3% RMS FOR INPUT DC RANGE    
OUTPUT FREQUENCY: 50 HZ ± 1%    
POWER FACTOR: 1.0    
OUTPUT WAVE FORM PURE SINE WAVE    
       
TRANSFER TIME: < 8ms    
BATTERY VOLTAGE: 48 VDC    
BATTERY CHARGER CURRENT 25 AMPS  
SOLAR REGULATOR CURRENT 30 AMPS    
       
DISPAY LCD UPS STATUS - INPUT VOLTAGE - OUTPUT VOLTAGE - MODEL  
  INPUT FREQUENCY - OUTPUT FREQUENCY - TEMPERATURE
  LOAD PRCENTAGE - BATTERY CAPACITY PERCENTAGE  
     
AC FAIL BEEPING EVERY 4 SECONDS  
LOW BATTERY BEEPING EVERY SECOND  
UPS FAULT BEEPING CONTINUOSLY  
OVERLOAD BEEPING TWICE PER SECOND  
OPERATIONAL TEMPERATURE 0-40 DEGREE CELCIUS  
RELATIVE HUMIDITY 0-95% NON-CONDENSING  
AUDIBLE NOISE LESS THAN 55dBA @ 1M  
NET WEIGHT 70 KG  
DIMENSION (WXHXD) mm 390 X 550 X 235
Uninterruptable Power Source

The Home UPS is a microprocessor based Pure Sine Wave UPS with remarkable features and performance, which may be used widely in different applications. The range of product offers durable and reliable source of backup power. It is one of very few products on the market offering unsurpassed clean, True Sine Wave power combined with a 24 Hour operation capability and is cable of delivering uninterrupted power to almost any application or appliance.

 

Applications

Of the many appliances or products other products are not able to power; The Home-UPS Range is capable of supplying power to

  • Home Appliances
  • Consumer Electronics
  • Lighting
  • Garage and Gate Motors
  • Heating Systems
  • Fridges
  • Air Conditioners
  • Water Pumps
  • Laser printers
  • Office Equipment amongst others.
Durability

The units produce excellent results in harsh environments and have built in isolation transformers not allowing interferences or reducing the potential of Electro-magnetic forces from equipment or appliances to hamper its operation.

 

Operation and Programmability
LCD Menu Options
Output Voltage & Frequency Adjustment     220VAC \ 230Vac \ 240VAC 50Hz or 60Hz
Input Voltage and Frequency Display     Displays the present Input Voltage and Frequency
Output Voltage and Frequency Display   Displays the present Output Voltage and Frequency
Charging Current Adjustment  100A/h \ 200A/h \ 300A/h \ 400A/h \ 600A/h
Battery Status Display     Battery Voltage \ Battery Capacity
Output Power Usage Display  Percentage of Output Power Usage is displayed
Temperature Display       Display of Internal Temperature
History Events                                                   New & Old AC Fail and Overload Counts
Fan Control

The Home-Ups has Intelligent fan speed control and detection
The 4-Stage fan speed control is load dependant and provides fan failure detection sending a warning messages to the LCD panel.

 

Generator Integration

The Home-ups series may be integrated with a generator in order to increase backup Time or provide an immediate backup during the start-up of the generator. The Over Voltage Protection allows monitoring and switchover on over voltage conditions.
The units currently boast one of the best price / performance ratios in the industry.

 

Other True Sine Wave inverters

Other products currently on the market, either True Sine wave or Modified do not always have the capability of supplying a reliable source of power for either part or the entire household or business. High quality industrial communication Inverters supplied to the likes of the telecommunications and cellular industries generally only supply power to standard linear loads without a varying output requirement. When these units are put into the household or business environment, where high peak demands are required the units very often fall short, as with my personal experience have up to a 20% failure rate. This is not due to the product being badly manufactured. It was not designed for the application at hand.

 

Modified Wave form inverters

Modified sine wave inverters are not meant to be operated under a high load demand for hours at a time, and should only be utilized as a temporary basic backup solutions, such as a few lights and tv only, or computer, at not more than 1000 watts, 2000VA.Other Inverter, UPS related advertisements may be misleading as to the amount of power to be supplied for the period necessary.

 

Generator Vs Home-Ups

Generators are bulky, cumbersome, costly, high maintenance, noisy and not very environmentally friendly. Although they do have their own place in the market, should be utilized for their specific purpose. As the demand has grown for backup systems we have seen massive increases in fuel prices. These
products currently pollute many suburbs with their noise and emissions generated when in use. The current laws concerning noise emissions for 45db at night and 55db during the day are very rarely compliant. They are not very user friendly and at the best of times are harm full both to the users, dependants and the environment.
Although some generators may initially be an inexpensive source of backup power, over the months and years costs add up rather dramatically. They have many moving parts requiring maintenance the same as any other petrol or diesel driven engine. They currently cost in the order of R 7.20~R 15.00 per KW per hour to operate. Should you not utilize these items at a 50% or more capacity of the unit they are likely to be damaged. Many of the cheaper generator solutions do not offer a very stable regulated output. There has been many instances of appliances and products being damaged where ups’s have had to be
purchased over and above the generator in order to try and maintain a stable source of energy.

 

Home Ups-Warranty

As a standard offered by the manufacturer of the Home-Ups Series Products, all units supplied have a 1 Year Manufacturer and components Warranty, and a 7 days on site service and replacement after signed off, and commissioned. Items must be installed with accordance to SANS0142-1/2006 for the wiring of premises’ for low voltage installation’s.
Batteries supplied have a one year warranty based on faulty cells, and not capacity retention. It is the requirement of the customer and sales person alike to ensure an appropriate battery set is supplied with all products based on load and backup time requirements.


For Further Pricing and online purchases please visit - http://www.cornerstonepowerproducts.co.za - Dynamic Power Solutions
Home - Switchmode AC DC Power Supply - Switchmode DC DC Converter - DC AC Inverters - Ups and Power Backup Systems - Batteries - Battery Cabinets - Solar Products - Wind Turbines

© Copyright 2008, Cornerstone Power Products, © Copyright 2008, Mantech Electronics (Pty) Ltd. All rights reserved.
All brands, trademarks, tradenames, and logos are the
property of their respective owners